1.
China Pharmacist ; (12): 188-190, 2014.
Article in Chinese | WPRIM | ID: wpr-452838

ABSTRACT

Objective:To establish the determination method for four lurasidone hydrochloride enantiomers by HPLC. Methods:Lurasidone hydrochloride enantiomers were separated on a CHIRALPAK AD-H column (250 mm × 4. 6 mm, 5μm). The mobile phase consisted of hexane-ethanol-diethylamine ( 90∶10∶0. 1) at a flow rate of 1. 0 ml·min-1 and the column temperature was at 40℃. The detection wavelength was 230nm. Results:The resolution of lurasidone hydrochloride enantiomers was above 2. 0. The linear calibra-tion curves were obtained over the range of 5-120 μg· ml-1 for all the enantiomers (r=0. 999 9). The recovery was above 99. 0%with RSD below 0. 5%. The detection limits were 5ng. Conclusion:The method is simple, accurate and rapid, and suitable for the de-termination and quality control.